CAS PD2 TO SPS 2000

CAS PDII SETTINGS TO LINK TO SPS2000

 

The SPS2000 supports the connection of a Cas PDII scale from eprom Version 1.60 or above. Following are the setup instructions to connect the SPS2000 and scale with details on how to operate this.

 

It should be noted if connecting to an existing PDII this will require an upgrade which can be obtained from your provider, and once upgraded the scale will need recalibrating using a complete weight set 15Kilo. The scale also requires setting to Type 4. To set, power off the scale and hold the TARE key. Power on and press the * key to change to Type 4, press the ZERO key to finish.

 

Please note when backing up a program to SD card from an SPS2000 V1.50 and loading to the V1.60 or above EPROM, do not transfer the P mode system options, these will need to be entered manually.

 

Defining the Port

 

In S-mode select Define Port

Choose the Port the Cas Scale will be connected to by pressing Serial Port #1 in the top left hand corner

Ensure the follow options are set:

 

Baud Rate - 9600
Parity - Odd
Data Bits - 7
Stop Bits - 1

 

Select Device then press Scale and ensure CAS PDII is selected

Press OK to exit

 
 

 

Programming the PLU Status Group

 

Select the P-mode tab followed by the PLU option.

Press the PLU Status Group button and select the Status Group that will be set as Scaleable.

Select the Option#2 tab

Set Option 13. Is PLU Scaleable? and Option 14. Auto Scale on this PLU? to Yes

Press Close to Exit

 

 

 

Programming the PLU’s

 

Within P-mode select the PLU option followed by PLU Add & Change

Select the first PLU to be Scaleable

Select the PLU Status Group Link # option and enter the number of the Status Group which has previously been set as scaleable.

Select the Prices tab and ensure the Price per Kilo is set in the PRC/HALO field

Repeat this for all PLU’s which need to be Scaleable

Press Close to exit

 

 

 

 
   
       
 
Date 24/01/07

Page No.

2/2

Manufacturer Sam4s

Model

SPS2000

Version V1.50 or Above

Software

N/A

 

 

 

 

 

Date 24/01/07

Page No.

2/2

Manufacturer Sam4s

Model

SPS2000

Version V1.50 or Above

Software

N/A

 

 

 

 

 

This entry was posted in   CAS.
Bookmark the   permalink.

Langley Distribution has written 42 articles